Download PDF

PH 2400 SERIES - HFM

Structure Annular corrugated Hydroformed flexible metal hoses produced from longitudinally welded tubes with or without braiding

Characteristics Light Weight / Medium Flexibility

Standards EN ISO 10380

Hose Material Stainless Steel AISI 304, AISI 321, AISI 316L

Braiding Material Stainless Steel AISI 304 and AISI 316L

Suitable Fittings Types Threaded end, Flange end, Pipe end etc as per customer specifications

Note: Please Contact our sales team for Specific Length

product img

METRIC SYSTEM :

Item Code DN
img
Tube ID
img
Tube OD
img
Braid OD
img
Tol
Braid
img
BR/r
img
WP
img
BP
img
W
(D) (D1) (D2) (Dx) Coverage Static Dynamic SWB*
W.P (Max)
DWB
W.P (Max)
SWB
B.P (Min)
SWB
Weight
DWB
Weight
mm mm mm mm % mm mm bar bar bar Kg/m Kg/m
R032HFMXR10 32 31.6 43.2 44.8 ± 0.50 90 105 300 30 45 120 0.75 1.11
R040HFMXR10 40 40.3 51.5 53.1 ± 0.50 92 130 340 30 45 120 1.05 1.61
R050HFMXR10 50 49.5 62.7 64.3 ± 1.00 96 160 390 24 36 96 1.27 1.88
R065HFMXR10 65 64.8 78.3 80.3 ± 1.00 94 200 460 22 33 88 1.88 2.91
R080HFMXR10 80 79.8 96.5 98.5 ± 1.00 96 240 660 18 27 72 2.35 3.54
R100HFMXR10 100 99.8 116.2 118.2 ± 1.00 94 290 750 16 24 64 2.89 4.36
R125HFMXR10 125 130 154 157.5 ± 1.50 92 350 1000 14 21 56 5.13 7.44
R150HFMXR10 150 154 180.5 182.5 ± 1.50 90 400 1250 10 15 40 5.91 8.40
R200HFMXR10 200 204 233.4 236 ± 1.50 90 520 1600 8 12 32 8.64 11.69
R250HFMXR10 250 254 282 285 ± 1.50 90 620 2000 7.5 11.25 30 13.97 19.62

NOTE:

1. Test Pressure is 1.5 times of Working Pressure @ 20°C.

2. SWB - Single Wire Braid, DWB - Double Wire Braid, WP - Working Pressure, BP - Burst Pressure.

3. Contact Factory for Temperature correction Factor.

4. THESE INFORMATIONS ARE FOR GUIDANCE ONLY, WE RESERVE THE RIGHT TO ALTER (OR) AMEND SPECIFICATIONS AS DEEMED NECESSARY.

5. General Tolerance is applicable.

product img

IMPERIAL SYSTEM :

Item Code DN Braid Construction
(No of Carriers X No od Strands
X Wire Diameter)
img
Braid
img
ID
img
OD
img
WP
img
BP
img
BR/r
img
W
Coverage (D) (D1 & D2) W.P (Max) 70°F B.P (Max) 70°F Dynamic Static Weight per Foot
% inch inch psi psi inch inch lbs
R032HFMX000 1 1/4" 48 X 8 X 0.016 92 1.24 1.70 17 --- 11.81 4.13 0.26
R032HFMXR10 1 1/4" 48 X 8 X 0.016 92 1.24 1.78 435 1740 11.81 4.13 0.59
R032HFMXR20 1 1/4" 48 X 8 X 0.016 92 1.24 1.83 653 2612 11.81 4.13 0.93
R040HFMX000 1 1/2" 48 X 9 X 0.016 92 1.59 2.03 17 --- 13.39 5.12 0.33
R040HFMXR10 1 1/2" 48 X 9 X 0.016 92 1.59 2.09 435 1740 13.39 5.12 0.71
R040HFMXR20 1 1/2" 48 X 9 X 0.016 92 1.59 2.15 653 2612 13.39 5.12 1.08
R050HFMX000 2" 48 X 10 X 0.016 96 1.95 2.47 15 --- 15.35 6.30 0.44
R050HFMXR10 2" 48 X 10 X 0.016 96 1.95 2.53 348 1392 15.35 6.30 0.85
R050HFMXR20 2" 48 X 10 X 0.016 96 1.95 2.59 522 2088 15.35 6.30 1.27
R065HFMX000 2 1/2" 72 X 7 X 0.020 94 2.55 3.08 12 --- 18.11 7.87 0.57
R065HFMXR10 2 1/2" 72 X 7 X 0.020 94 2.55 3.16 319 1276 18.11 7.87 1.26
R065HFMXR20 2 1/2" 72 X 7 X 0.020 94 2.55 3.24 479 1916 18.11 7.87 1.96
R080HFMX000 3" 72 X 8 X 0.020 96 3.14 3.80 10 --- 25.98 9.45 0.77
R080HFMXR10 3" 72 X 8 X 0.020 96 3.14 3.88 261 1044 25.98 9.45 1.58
R080HFMXR20 3" 72 X 8 X 0.020 96 3.14 3.95 392 1568 25.98 9.45 2.38
R100HFMX000 4" 72 X 10 X 0.020 94 3.93 4.58 8 --- 29.53 11.42 0.95
R100HFMXR10 4" 72 X 10 X 0.020 94 3.93 4.65 232 928 29.53 11.42 1.94
R100HFMXR20 4" 72 X 10 X 0.020 94 3.93 4.73 348 1392 29.53 11.42 2.93
R125HFMX000 5" 72 X 10 X 0.024 92 5.12 6.06 6 --- 39.37 13.78 1.95
R125HFMXR10 5" 72 X 10 X 0.024 92 5.12 6.20 203 812 39.37 13.78 3.44
R125HFMXR20 5" 72 X 10 X 0.024 92 5.12 6.30 305 1220 39.37 13.78 4.94
R150HFMX000 6" 72 X 11 X 0.024 90 6.06 7.11 5 --- 49.21 15.75 2.30
R150HFMXR10 6" 72 X 11 X 0.024 90 6.06 7.21 145 580 49.21 15.75 3.97
R150HFMXR20 6" 72 X 11 X 0.024 90 6.06 7.28 218 872 49.21 15.75 5.64
R200HFMX000 8" 96 X 9 X 0.026 90 8.03 9.19 5 --- 62.99 20.47 3.76
R200HFMXR10 8" 96 X 9 X 0.026 90 8.03 9.33 116 464 62.99 20.47 5.81
R200HFMXR20 8" 96 X 9 X 0.026 90 8.03 9.40 174 696 62.99 20.47 7.86
R250HFMX000 10" 96 X 12 X 0.028 90 10.00 11.1 3 --- 78.74 24.41 5.59
R250HFMXR10 10" 96 X 12 X 0.028 90 10.00 11.22 109 436 78.74 24.41 9.39
R250HFMXR20 10" 96 X 12 X 0.028 90 10.00 11.33 163 652 78.74 24.41 13.19

NOTE:

1. Test Pressure is 1.5times of Working Pressure @ 70°F.

2. WP - Working Pressure, BP - Burst Pressure.

3. Contact Factory for Temperature correction Factor.

4. THESE INFORMATIONS ARE FOR GUIDANCE ONLY, WE RESERVE THE RIGHT TO ALTER (OR) AMEND SPECIFICATIONS AS DEEMED NECESSARY

5. General Tolerance is applicable.

Go to Top